Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Clin Nucl Med ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630948

RESUMO

PURPOSE OF THE REPORT: 18F-PBR06-PET targeting 18-kDa translocator protein can detect abnormal microglial activation (MA) in multiple sclerosis (MS). The objectives of this study are to develop individualized mapping of MA using 18F-PBR06, to determine the effect of disease-modifying treatment (DMT) efficacy on reducing MA, and to determine its clinical, radiological, and serological correlates in MS patients. PATIENTS AND METHODS: Thirty 18F-PBR06-PET scans were performed in 22 MS patients (mean age, 46 ± 13 years; 16 females) and 8 healthy controls (HCs). Logarithmically transformed "glial activity load on PET" scores (calculated as the sum of voxel-by-voxel z-scores ≥4), "lnGALP," were compared between MS and HC and between MS subjects on high-efficacy DMTs (H-DMT, n = 13) and those on no or lower-efficacy treatment, and correlated with clinical measures, serum biomarkers, and cortical thickness. RESULTS: Cortical gray matter (CoGM) and white matter (WM) lnGALP scores were higher in MS versus HC (+33% and +48%, P < 0.001). In H-DMT group, CoGM and WM lnGALP scores were significantly lower than lower-efficacy treatment (P < 0.01) but remained abnormally higher than in HC group (P = 0.006). Within H-DMT patients, CoGM lnGALP scores correlated positively with physical disability, fatigue and serum glial fibrillary acid protein levels (r = 0.65-0.79, all P's < 0.05), and inversely with cortical thickness (r = -0.66, P < 0.05). CONCLUSIONS: High-efficacy DMTs decrease, but do not normalize, CoGM and WM MA in MS patients. Such "residual" MA in CoGM is associated with clinical disability, serum biomarkers, and cortical degeneration. Individualized mapping of translocator protein PET using 18F-PBR06 is clinically feasible and can potentially serve as an imaging biomarker for evaluating "smoldering" inflammation in MS patients.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38193678

RESUMO

AIMS: In systemic light-chain (AL) amyloidosis, quantification of right ventricular (RV) amyloid burden has been limited and the pathogenesis of RV dysfunction is poorly understood. Using 18F-florbetapir positron emission tomography/computed tomography (PET/CT), we aimed to quantify RV amyloid, correlate RV amyloid with RV structure and function, determine the independent contributions of RV, left ventricular (LV) and lung amyloid to RV function, and to associate RV amyloid with major adverse cardiac events (MACE: death, heart failure hospitalization, cardiac transplantation). METHODS AND RESULTS: We prospectively enrolled 106 participants with AL amyloidosis (median age 62 years, 55% males) who underwent 18F-florbetapir PET/CT, magnetic resonance imaging and echocardiography. 18F-florbetapir PET/CT identified RV amyloid in 63% of those with, and 40% of those without cardiac involvement by conventional criteria. RV amyloid burden correlated with RV ejection fraction (EF), RV free wall longitudinal strain (FWLS), RV wall thickness, RV mass index, NT-proBNP, troponin T, LV amyloid and lung amyloid (each p<0.001). In multivariable analysis, RV amyloid burden, but not LV or lung amyloid burden, predicted RV dysfunction (EF p=0.014; FWLS p<0.001). During a median follow-up of 28 months, RV amyloid burden predicted MACE (p<0.001). CONCLUSIONS: This study shows for the first time that 18F-florbetapir PET/CT identifies early RV amyloid in systemic AL amyloidosis prior to alterations in RV structure and function. Increasing RV amyloid on 18F-florbetapir PET/CT is associated with worse RV structure and function, predicts RV dysfunction and predicts MACE. These results imply a central role for RV amyloid in the pathogenesis of RV dysfunction.

3.
J Nucl Med ; 64(Suppl 2): 20S-28S, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37918844

RESUMO

Myocardial infiltration by amyloid fibrils causes a severe and progressive form of heart failure. Until recently, this was not treatable. Several novel therapies have recently become available, increasing the urgency to make an accurate diagnosis, evaluate risk, and determine treatment response. Molecular imaging with positron-emitting amyloid tracers has a key emerging role in the evaluation and management of cardiac amyloidosis. In this review, we discuss molecular imaging of cardiac amyloidosis using amyloid PET tracers, including recent advances with a focus on the future.


Assuntos
Amiloidose , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Amiloidose/diagnóstico por imagem , Amiloide , Miocárdio , Imagem Molecular , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia
4.
medRxiv ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37873250

RESUMO

Aims: In systemic light-chain (AL) amyloidosis, cardiac involvement portends poor prognosis. Using myocardial characteristics on magnetic resonance imaging (MRI), this study aimed to detect early myocardial alterations, to analyze temporal changes with plasma cell therapy, and to predict risk of major adverse cardiac events (MACE) in AL amyloidosis. Methods and Results: Participants with recently diagnosed AL amyloidosis were prospectively enrolled. Presence of AL cardiomyopathy (AL-CMP vs. AL-non-CMP) was determined by abnormal cardiac biomarkers. MRI was performed at baseline and 6 months, with 12-month imaging in AL-CMP cohort. MACE was defined as all-cause death, heart failure hospitalization, or cardiac transplantation. Mayo AL stage was based on troponin T, NT-proBNP, and difference in free light chains. The study cohort included 80 participants (median age 62 years, 58% males). Median left ventricular extracellular volume (ECV) was significantly higher in AL-CMP (53% vs. 30%, p<0.001). ECV was abnormal (>32%) in all AL-CMP and in 47% of AL-non-CMP. ECV tended to increase at 6 months and decreased significantly from 6 to 12 months in AL-CMP (median -3%, p=0.011). ECV was strongly associated with MACE (p<0.001), and improved MACE prediction when added to Mayo AL stage (p=0.002). ECV≤32% identified a cohort without MACE, while ECV>48% identified a cohort with 74% MACE. Conclusions: In AL amyloidosis, ECV detects subclinical cardiomyopathy. ECV tends to increase from baseline to 6 months and decreases significantly from 6 and 12 months of plasma cell therapy in AL-CMP. ECV provides excellent risk stratification and offers additional prognostic performance over Mayo AL stage.

5.
JACC Cardiovasc Imaging ; 16(11): 1419-1432, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37676210

RESUMO

BACKGROUND: Cardiac amyloid quantification could advance early diagnosis of amyloid cardiomyopathy (CMP) and treatment monitoring. However, current imaging tools are based on indirect measurements. 124I-evuzamitide is a novel pan-amyloid radiotracer binding to amyloid deposits from multiple amyloidogenic proteins. Its ability to quantify cardiac amyloid has not yet been investigated. OBJECTIVES: The objectives of this pilot study were to quantify myocardial 124I-evuzamitide uptake and to compare its diagnostic value to 18F-florbetapir in participants with amyloid CMP and control subjects. METHODS: This study included 46 participants: 12 with light-chain (AL) CMP, 12 with wild-type transthyretin (ATTRwt) CMP, 2 with hereditary amyloidosis, and 20 control subjects. All amyloidosis participants underwent positron emission tomography/computed tomography with 124I-evuzamitide and 18F-florbetapir. Control subjects underwent 124I-evuzamitide (n = 10) or 18F-florbetapir (n = 8) positron emission tomography/computed tomography. Left ventricular percent injected dose (LV% ID) was measured as mean activity concentration × myocardial volume/injected activity. High LV %ID was defined using Youden's index. RESULTS: In CMP participants, median age was 74 years and 92% were men. 124I-evuzamitide LV %ID differed across groups: median AL-CMP 1.48 (IQR: 1.12-1.89), ATTRwt-CMP 2.12 (IQR: 1.66-2.47), and control subjects 0.00 (IQR: 0.00-0.01; overall P < 0.001). High LV %ID perfectly discriminated CMP from control subjects. Discrimination performance was similar for 18F-florbetapir LV %ID. Notably, for ATTRwt-CMP, LV %ID was higher with 124I-evuzamitide than 18F-florbetapir (P = 0.002). 124I-evuzamitide LV %ID was correlated with interventricular septum thickness (Spearman's ρ = 0.78) and LV global longitudinal strain (ρ = 0.54) from echocardiography, and with LV mass index (ρ = 0.82) and extracellular volume (ρ = 0.51) from cardiac magnetic resonance. CONCLUSIONS: 124I-evuzamitide demonstrates uptake by cardiac amyloid and accurately discriminates amyloid CMP from control subjects. In AL-CMP, discrimination performance is similar to 18F-florbetapir. In ATTRwt-CMP, performance may be better with 124I-evuzamitide. Moderate-to-strong correlations of 124I-evuzamitide uptake with cardiac structural and functional metrics suggest valid amyloid quantification. Hence, 124I-evuzamitide is a promising novel radiotracer to detect and quantify cardiac amyloid.


Assuntos
Amiloidose , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Masculino , Humanos , Idoso , Feminino , Projetos Piloto , Valor Preditivo dos Testes , Amiloide , Proteínas Amiloidogênicas/metabolismo
6.
Circ Cardiovasc Imaging ; 16(9): e015324, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37655498

RESUMO

BACKGROUND: Given the central importance of cardiorenal interactions, mechanistic tools for evaluating cardiorenal physiology are needed. In the heart and kidneys, shared pathways of neurohormonal activation, hypertension, and vascular and interstitial fibrosis implicate the relevance of systemic vascular health. The availability of a long axial field of view positron emission tomography (PET)/computed tomography (CT) system enables simultaneous evaluation of cardiac and renal blood flow. METHODS: This study evaluated the feasibility of quantification of renal blood flow using data acquired during routine, clinically indicated 13N-ammonia myocardial perfusion PET/CT. Dynamic PET image data were used to calculate renal blood flow. Reproducibility was assessed by the intraclass correlation coefficient among 3 independent readers. PET-derived renal blood flow was correlated with imaging and clinical parameters in the overall cohort and with histopathology in a small companion study of patients with a native kidney biopsy. RESULTS: Among 386 consecutive patients with myocardial perfusion PET/CT, 296 (76.7%) had evaluable images to quantify renal perfusion. PET quantification of renal blood flow was highly reproducible (intraclass correlation coefficient 0.98 [95% CI, 0.93-0.99]) and was correlated with the estimated glomerular filtration rate (r=0.64; P<0.001). Compared across vascular beds, resting renal blood flow was correlated with maximal stress myocardial blood flow and myocardial flow reserve (stress/rest myocardial blood flow), an integrated marker of endothelial health. In patients with kidney biopsy (n=12), resting PET renal blood flow was strongly negatively correlated with histological interstitial fibrosis (r=-0.85; P<0.001). CONCLUSIONS: Renal blood flow can be reliably measured from cardiac 13N-ammonia PET/CT and allows for simultaneous assessment of myocardial and renal perfusion, opening a potential novel avenue to interrogate the mechanisms of emerging therapies with overlapping cardiac and renal benefits.


Assuntos
Amônia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Tomografia por Emissão de Pósitrons , Rim/diagnóstico por imagem , Perfusão , Fibrose
7.
medRxiv ; 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37745589

RESUMO

Background: Myocardial immunoglobulin light-chain (AL) amyloid deposits trigger heart failure, cardiomyocyte stretch and myocardial injury, leading to adverse cardiac outcomes. Positron emission tomography/computed tomography (PET/CT) with 18 F-florbetapir, a novel amyloid-targeting radiotracer, can quantify left ventricular (LV) amyloid burden, but its prognostic value is not known. Therefore, we aimed to evaluate the prognostic value of LV amyloid burden quantified by 18 F-florbetapir PET/CT and to identify mechanistic pathways mediating its association with outcomes. Methods: Eighty-one participants with newly-diagnosed systemic AL amyloidosis were prospectively enrolled and underwent 18 F-florbetapir PET/CT. LV amyloid burden was quantified using 18 F-florbetapir LV percent injected dose (%ID). Mayo AL stage was determined using troponin T, N-terminal pro-B-type natriuretic peptide (NT-proBNP), and difference between involved and uninvolved free light chain levels. Major adverse cardiac events (MACE) were defined as all-cause death, heart failure hospitalization, or cardiac transplantation within 12 months. Results: Among participants (median age 61 years, 57% males), 36% experienced MACE. Incidence of MACE increased across tertiles of LV amyloid burden from 7% to 63% (p<0.001). LV amyloid burden was significantly associated with MACE in univariable analysis (hazard ratio 1.45, 95% confidence interval 1.15-1.82, p=0.002). However, this association became non-significant in multivariable analyses adjusted for Mayo AL stage. Mediation analysis showed that the association between 18 F-florbetapir LV %ID and MACE was primarily mediated by NT-proBNP (p<0.001), a marker of cardiomyocyte stretch and component of Mayo AL stage. Conclusion: In this first study to link cardiac 18 F-florbetapir uptake to subsequent outcomes, LV amyloid burden estimated by LV %ID predicted MACE in AL amyloidosis. But this effect was not independent of Mayo AL stage. LV amyloid burden was associated with MACE primarily via NT-pro-BNP, a marker of cardiomyocyte stretch and component of Mayo AL stage. These findings provide novel insights into the mechanism through which myocardial AL amyloid leads to MACE. Clinical Perspective: In systemic light-chain (AL) amyloidosis, cardiac involvement is the key determinant of adverse outcomes. Usually, prognosis is based on the Mayo AL stage, determined by troponin T, N-terminal pro-B-type natriuretic peptide (NT-proBNP), and the difference between involved and uninvolved immunoglobulin free light chain levels (dFLC). Cardiac amyloid burden is not considered in this staging. In the present study, we used the amyloid-specific radiotracer 18 F-florbetapir to quantify left ventricular (LV) amyloid burden in 81 participants with newly-diagnosed AL amyloidosis and evaluated its prognostic value on major adverse outcomes (MACE: all-cause death, heart failure hospitalization, or cardiac transplantation within 12 months). We found that higher LV amyloid burden by 18 F-florbetapir positron emission tomography/computed tomography (PET/CT) was strongly associated with MACE. However, this association became non-significant after adjustment for the Mayo AL stage. Mediation analysis offered novel pathophysiological insights, implying that LV amyloid burden leads to MACE predominantly through cardiomyocyte stretch and light chain toxicity (by NT-proBNP), rather than through myocardial injury (by troponin T), also considering the severity of plasma cell dyscrasia (by dFLC). This mediation by NT-proBNP may explain why the association with outcomes was non-significant with adjustment for Mayo AL stage. Together, these results establish quantitative 18 F-florbetapir PET/CT as a valid method to predict adverse outcomes in AL amyloidosis. These results support the use of 18 F-florbetapir PET/CT to measure the effects of novel fibril-depleting therapies, in addition to plasma cell therapy, to improve outcomes in systemic AL amyloidosis.

9.
Circ Cardiovasc Imaging ; 15(6): e013987, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35674051

RESUMO

BACKGROUND: Single photon emission computed tomography (SPECT) has limited ability to identify multivessel and microvascular coronary artery disease. Gamma cameras with cadmium zinc telluride detectors allow the quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR). However, evidence of its accuracy is limited, and of its reproducibility is lacking. We aimed to validate 99mTc-sestamibi SPECT MBF and MFR using standard and spline-fitted reconstruction algorithms compared with 13N-ammonia positron emission tomography in a cohort of patients with known or suspected coronary artery disease and to evaluate the reproducibility of this technique. METHODS: Accuracy was assessed in 34 participants who underwent dynamic 99mTc-sestamibi SPECT and 13N-ammonia positron emission tomography and reproducibility in 14 participants who underwent 2 99mTc-sestamibi SPECT studies, all within 2 weeks. A rest/pharmacological stress single-day SPECT protocol was performed. SPECT images were reconstructed using a standard ordered subset expectation maximization (OSEM) algorithm with (N=21) and without (N=30) application of spline fitting. SPECT MBF was quantified using a net retention kinetic model' and MFR was derived as the stress/rest MBF ratio. RESULTS: SPECT global MBF with splines showed good correlation with 13N-ammonia positron emission tomography (r=0.81, P<0.001) and MFR estimates (r=0.74, P<0.001). Correlations were substantially weaker for standard reconstruction without splines (r=0.61, P<0.001 and r=0.34, P=0.07, for MBF and MFR, respectively). Reproducibility of global MBF estimates with splines in paired SPECT scans was good (r=0.77, P<0.001), while ordered subset expectation maximization without splines led to decreased MBF (r=0.68, P<0.001) and MFR correlations (r=0.33, P=0.3). There were no significant differences in MBF or MFR between the 2 reproducibility scans independently of the reconstruction algorithm (P>0.05 for all). CONCLUSIONS: MBF and MFR quantification using 99mTc-sestamibi cadmium zinc telluride SPECT with spatiotemporal spline fitting improved the correlation with 13N-ammonia positron emission tomography flow estimates and test/retest reproducibility. The use of splines may represent an important step toward the standardization of SPECT flow estimation.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Amônia , Cádmio , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco
10.
Artigo em Inglês | MEDLINE | ID: mdl-35091466

RESUMO

BACKGROUND AND OBJECTIVES: This [18F]fluorodeoxyglucose (FDG) PET study evaluates the accuracy of semiquantitative measurement of putaminal hypermetabolism in identifying anti-leucine-rich, glioma-inactivated-1 (LGI1) protein autoimmune encephalitis (AE). In addition, the extent of brain dysmetabolism, their association with clinical outcomes, and longitudinal metabolic changes after immunotherapy in LGI1-AE are examined. METHODS: FDG-PET scans from 49 age-matched and sex-matched subjects (13 in LGI1-AE group, 15 in non-LGI1-AE group, 11 with Alzheimer disease [AD], and 10 negative controls [NCs]) and follow-up scans from 8 patients with LGI1 AE on a median 6 months after immunotherapy were analyzed. Putaminal standardized uptake value ratios (SUVRs) normalized to global brain (P-SUVRg), thalamus (P/Th), and midbrain (P/Mi) were evaluated for diagnostic accuracy. SUVRg was applied for all other analyses. RESULTS: P-SUVRg, P/Th, and P/Mi were higher in LGI1-AE group than in non-LGI1-AE group, AD group, and NCs (all p < 0.05). P/Mi and P-SUVRg differentiated LGI1-AE group robustly from other groups (areas under the curve 0.84-0.99). Mediotemporal lobe (MTL) SUVRg was increased in both LGI1-AE and non-LGI1-AE groups when compared with NCs (both p < 0.05). SUVRg was decreased in several frontoparietal regions and increased in pallidum, caudate, pons, olfactory, and inferior occipital gyrus in LGI1-AE group when compared with that in NCs (all p < 0.05). In LGI1-AE group, both MTL and putaminal hypermetabolism were reduced after immunotherapy. Normalization of regional cortical dysmetabolism associated with clinical improvement at the 6- and 20-month follow-up. DISCUSSION: Semiquantitative measurement of putaminal hypermetabolism with FDG-PET may be used to distinguish LGI1-AE from other pathologies. Metabolic abnormalities in LGI1-AE extend beyond putamen and MTL into other subcortical and cortical regions. FDG-PET may be used in evaluating disease evolution in LGI1-AE. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that semiquantitative measures of putaminal metabolism on PET can differentiate patients with LGI1-AE from patients without LGI1-AE, patients with AD, or NCs.


Assuntos
Doença de Alzheimer , Córtex Cerebral/metabolismo , Doenças Autoimunes Desmielinizantes do Sistema Nervoso Central , Encefalite , Peptídeos e Proteínas de Sinalização Intracelular , Mesencéfalo/metabolismo , Putamen/metabolismo , Adolescente , Adulto , Idoso , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/imunologia , Doença de Alzheimer/metabolismo , Doença de Alzheimer/fisiopatologia , Autoanticorpos , Córtex Cerebral/diagnóstico por imagem , Doenças Autoimunes Desmielinizantes do Sistema Nervoso Central/diagnóstico por imagem , Doenças Autoimunes Desmielinizantes do Sistema Nervoso Central/imunologia , Doenças Autoimunes Desmielinizantes do Sistema Nervoso Central/metabolismo , Doenças Autoimunes Desmielinizantes do Sistema Nervoso Central/fisiopatologia , Eletroencefalografia , Encefalite/diagnóstico por imagem , Encefalite/imunologia , Encefalite/metabolismo , Encefalite/fisiopatologia , Feminino , Seguimentos , Humanos , Peptídeos e Proteínas de Sinalização Intracelular/imunologia , Imageamento por Ressonância Magnética , Masculino , Mesencéfalo/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Putamen/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
11.
JACC Cardiovasc Imaging ; 15(4): 594-603, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34922860

RESUMO

OBJECTIVES: The goals of this study were to characterize myocardial composition during the active and remission phases of light-chain (AL) cardiac amyloidosis. BACKGROUND: Cardiac dysfunction in AL amyloidosis is characterized by dual insults to the myocardium from infiltration and toxicity from light chains during the active phase and by infiltration alone in the remission phase. METHODS: Prospectively enrolled subjects with cardiac AL amyloidosis (21 remission AL amyloidosis; age: 63.4 ± 7.3 years; 47.6% male; and 48 active AL amyloidosis; age: 62.5 ± 7.4 years; 60.4% male) underwent contrast-enhanced cardiac magnetic resonance with T1 and T2 mapping and measurement of extracellular volume (ECV). By definition, serum free light-chain levels were normal for at least 1 year following successful AL therapy in the remission group and abnormal in the active group. RESULTS: Myocardial ECV was similarly expanded in the remission and active AL amyloidosis groups (0.488 ± 0.082 vs 0.519 ± 0.083, respectively; P = 0.15). However, myocardial T2 relaxation times (47.7 ± 3.2 ms vs 45.5 ± 3.0 ms; P = 0.008) as well as native T1 times (1,368 ms [IQR: 1,290-1,422 ms] vs 1,264 ms [IQR: 1,203-1,380 ms]; P = 0.024) were significantly higher in the remission compared to the active AL amyloidosis group. CONCLUSIONS: Myocardial ECV is substantially expanded in the active AL and remission AL cardiac amyloidosis groups, but native T1 values were higher, suggesting a different myocardial composition. There is no evidence of myocardial edema in active AL cardiac amyloidosis. Future phenotyping studies of AL cardiac amyloidosis need to consider complementary myocardial markers that define the interstitial milieu in addition to changes in extracellular volume. (Molecular Imaging of Primary Amyloid Cardiomyopathy; NCT02641145).


Assuntos
Amiloidose , Cardiomiopatias , Amiloidose de Cadeia Leve de Imunoglobulina , Idoso , Amiloidose/diagnóstico por imagem , Amiloidose/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Meios de Contraste , Feminino , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Amiloidose de Cadeia Leve de Imunoglobulina/patologia , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes
12.
Phys Med Biol ; 67(2)2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-34891142

RESUMO

Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as 'organ configuration motion' (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating duringin vivoPET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom andin vivodata into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.


Assuntos
Imagem Multimodal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Movimento (Física) , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos
13.
J Nucl Cardiol ; 29(2): 440-446, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32918247

RESUMO

AIM: The purpose of this study was to determine the inter- and intra-observer variability in 99mtechnetium-pyrophosphate (99mTc-PYP) scan interpretation for diagnosis of transthyretin cardiac amyloidosis (ATTR). METHODS AND RESULTS: Our study cohort comprised 100 consecutive subjects referred for 99mTc-PYP imaging based on clinical suspicion of ATTR cardiac amyloidosis. Myocardial 99mTc-PYP uptake was assessed by both visual (comparison of myocardial to rib uptake) and semi-quantitative (heart-to-contralateral lung uptake ratio, H:CL) methods. Twenty scans were analyzed twice, at least 48 hours apart, by each of two independent observers. Patients with visual scores of ≥ 2 on planar imaging as well as myocardial uptake on SPECT/CT were classified as ATTR positive. Diagnosis of ATTR by visual 99mTc-PYP grade was perfectly reproducible [concordance: positive and negative scans 100% (53/53 and 47/47, respectively). Both inter- and intra-observer correlations for H:CL ratio (r2 = 0.90, 0.99 (Observer 1) and 0.98 (Observer 2), respectively) and repeatability values on Bland-Altman plots were excellent. The coefficient of variation (%) for Observers 1 and 2 was 3.21 (2.14 to 4.29) and 7.49 (4.95 to 10.09), respectively. In addition, there was 100% concordance in positive and negative scan interpretation by visual grading between novice CV imagers (< 3 years' experience) and an experienced CV imager (10 years' experience). CONCLUSIONS: This study showed excellent inter-observer reproducibility and intra-observer repeatability of 99mTc-PYP visual scan interpretation and H:CL ratio for diagnosis of cardiac ATTR amyloidosis. Cardiac ATTR amyloidosis can be diagnosed reliably using 99mTc-PYP SPECT/CT by novice and experienced CV imagers.


Assuntos
Amiloidose , Cardiomiopatias , Difosfatos , Humanos , Pré-Albumina , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Pirofosfato de Tecnécio Tc 99m
14.
Surgery ; 171(1): 227-234, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34334212

RESUMO

BACKGROUND: Anaplastic thyroid cancer is a rare but devastating malignancy. Anaplastic thyroid cancer cells exhibit the Warburg effect by preferentially undergoing glycolysis even in aerobic conditions, leading to high glucose use. Here we assess if targeted inhibition of glycolysis can diminish anaplastic thyroid cancer growth and improve outcomes. METHODS: Human anaplastic thyroid cancer cell line 8505C was grown in medium containing high (25 mmol/L) or low (3 mmol/L) glucose concentration and hexokinase II inhibitor 3-bromopyruvate (200 µM). Cellular proliferation, migration, and invasion were measured. An orthotopic xenograft model of anaplastic thyroid cancer was generated in nude mice using 8505C cells. Animals were provided standard chow or a ketogenic diet and treated with 3-bromopyruvate (1.8 mg/kg). Overall survival time was monitored. Necropsies were performed to harvest tumors for analysis. RESULTS: Growth of 8505C in low-glucose medium with 3-bromopyruvate decreased cell proliferation by 89%, migration by 44%, and invasion by 73% (P < .001 for all) compared with high glucose. Animals concomitantly receiving a ketogenic diet and 3-bromopyruvate exhibited smaller tumor volumes (P = .03), slower tumor growth rates (P = .01), and improved overall survival (P = .006) compared with standard-diet control subjects. Monotherapy with a ketogenic diet or 3-bromopyruvate alone did not reduce tumor size or increase survival over the standard-diet control group. CONCLUSION: Glycolytic inhibition with 3-bromopyruvate inhibits tumor growth and extends survival in a murine model of anaplastic thyroid cancer when combined with the ketogenic diet. Thus, targeted glycolytic inhibition of anaplastic thyroid cancer exhibits context-specific utility and may only be effective during ketosis induced by dietary restriction of glycolytic inputs.


Assuntos
Dieta Cetogênica , Piruvatos/farmacologia , Carcinoma Anaplásico da Tireoide/terapia , Neoplasias da Glândula Tireoide/terapia , Efeito Warburg em Oncologia/efeitos dos fármacos , Animais , Linhagem Celular Tumoral , Proliferação de Células , Terapia Combinada/métodos , Feminino , Humanos , Camundongos , Piruvatos/uso terapêutico , Carcinoma Anaplásico da Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Carga Tumoral/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto
15.
Adv Ther (Weinh) ; 4(4)2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33997269

RESUMO

Glioblastoma multiforme (GBM) is the most common and deadliest form of brain tumor and remains amongst the most difficult cancers to treat. Brevican (Bcan), a central nervous system (CNS)-specific extracellular matrix protein, is upregulated in high-grade glioma cells, including GBM. A Bcan isoform lacking most glycosylation, dg-Bcan, is found only in GBM tissues. Here, dg-Bcan is explored as a molecular target for GBM. In this study, we screened a d-peptide library to identify a small 8-amino acid dg-Bcan-Targeting Peptide (BTP) candidate, called BTP-7 that binds dg-Bcan with high affinity and specificity. BTP-7 is preferentially internalized by dg-Bcan-expressing patient-derived GBM cells. To demonstrate GBM targeting, we radiolabeled BTP-7 with 18F, a radioisotope of fluorine, and found increased radiotracer accumulation in intracranial GBM established in mice using positron emission tomography (PET) imaging. dg-Bcan is an attractive molecular target for GBM, and BTP-7 represents a promising lead candidate for further development into novel imaging agents and targeted therapeutics.

16.
J Nucl Cardiol ; 28(5): 2004-2010, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31758410

RESUMO

BACKGROUND: 18F-florbetapir PET is emerging as an excellent quantitative tool to quantify cardiac light chain (AL) amyloidosis burden. The primary aim of this study was to determine interobserver reproducibility and intraobserver repeatability, defined per the recommendations of the Quantitative Imaging Biomarker Alliance technical performance group, of PET 18F-florbetapir retention index (RI) in patients with cardiac AL amyloidosis. METHODS: The study cohort comprised 37 subjects with systemic AL amyloidosis enrolled in the prospective study: Molecular Imaging of Primary Amyloid Cardiomyopathy (clinical trials.gov NCT: 02641145). Using 10 mCi of 18F-florbetapir, a 60-minute dynamic cardiac scan was acquired. Global and segmental left ventricular estimates of retention index (RI) of 18F-florbetapir were calculated (Carimas 2.9 software, Turku, Finland). RI was analyzed twice, at least 24 hours apart, by two independent observers. Intraobserver repeatability and interobserver reproducibility were evaluated using Bland-Altman plots and scatter plots with fitted linear regression curves. RESULTS: All reproducibility (interobserver, r = 0.98) and repeatability (intraobserver, R=0.99 for each observer) measures of 18F-florbetapir RI are excellent. On the Bland-Altman plots, the agreement limits for global 18F-florbetapir RI were high and ranged for reproducibility (interobserver) from - 9.3 to + 9.4% (Fig. 1), and for repeatability (observer 1 from - 10.8 to + 10.7% and from - 9.2 to + 11.4%, for observer 2). CONCLUSIONS: The present study showed excellent interobserver reproducibility and intraobserver repeatability of 18F-florbetapir PET retention index in patients with cardiac AL amyloidosis.


Assuntos
Amiloidose/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Idoso , Amiloidose/diagnóstico por imagem , Amiloidose/epidemiologia , Feminino , Finlândia/epidemiologia , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/enzimologia , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Reprodutibilidade dos Testes
17.
J Nucl Med ; 62(5): 716-722, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-32887756

RESUMO

The primary aims of this study were to determine the correlation between absolute quantitative 99mTc-pyrophosphate metrics and traditional measures of cardiac amyloid burden and to measure the intraobserver repeatability of the quantitative metrics. Methods: We studied 72 patients who underwent 99mTc-pyrophosphate SPECT/CT using a novel general-purpose cadmium-zinc-telluride-based SPECT/CT system. The clinical standard for these studies is visual grading (with grades of 0, 1, 2, and 3 indicating myocardial uptake absent, less than rib uptake, equal to rib uptake, or more than rib uptake, respectively). A visual grade of 2 or more was considered positive. For 72 patients, SUVmax, SUVmean, cardiac amyloid activity (CAA; i.e., SUVmean × left ventricular [LV] volume), and percentage injected dose (%ID) were calculated, and visual grading was performed. The correlation was determined between the 4 quantitative metrics or visual grades and the LV mass index (LVMI) (indexed to body surface area on echocardiography, 67 patients). For a subset of 11 patients, the correlation was determined between the visual or quantitative metrics and the extracellular volume (ECV) on cardiac MRI. Normal linear regression was used to compare the standardized association of each of the 4 quantitative metrics with LVMI, as a surrogate for amyloid burden. Receiver-operating-characteristic curve analysis was used to determine the diagnostic accuracy of quantitative metrics, using visual grading as the reference standard. The intraobserver repeatability of generating quantitative metrics was also determined. Results: All 4 quantitative metrics were highly accurate, with an area under the receiver-operating-characteristic curve of more than 0.96 for diagnosis of transthyretin cardiac amyloidosis. SUVmax, SUVmean, CAA, %ID, and visual grade were moderately positively correlated with LVMI (r = 0.485 for %ID) and strongly positively correlated, albeit in a small cohort, with ECV (r = 0.873, SUVmax). Intraobserver repeatability was excellent, with less than a 2% coefficient of variation for SUVmax, %ID, and CAA and 3.8% for SUVmean All 4 quantitative metrics had a standardized effect of more than 0.324 on LVMI; the largest standardized effect was 0.485, for %ID. Conclusion: In this first (to our knowledge) study of 99mTc-pyrophosphate cardiac imaging using a novel cadmium-zinc-telluride SPECT/CT scanner, SUVmax, SUVmean, CAA, and %ID measured by absolute quantitation of 99mTc-pyrophosphate were moderately correlated with LVMI and strongly correlated, albeit in a small cohort, with ECV. The intraobserver repeatability of generating the quantitative metrics was excellent.


Assuntos
Cádmio , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Pirofosfato de Tecnécio Tc 99m , Telúrio , Zinco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Artigo em Inglês | MEDLINE | ID: mdl-32769103

RESUMO

OBJECTIVE: The goal of our study is to assess the role of microglial activation in MS-associated fatigue (MSAF) using [F-18]PBR06-PET. METHODS: Fatigue severity was measured using the Modified Fatigue Impact Scale (MFIS) in 12 subjects with MS (7 relapsing-remitting and 5 secondary progressive) and 10 healthy control participants who underwent [F-18]PBR06-PET. The MFIS provides a total fatigue score as well as physical, cognitive, and psychosocial fatigue subscale scores. Standardized Uptake Value (SUV) 60-90 minute frame PET maps were coregistered to 3T MRI. Voxel-by-voxel analysis using Statistical Parametric Mapping and atlas-based regional analyses were performed. SUV ratios (SUVRs) were global brain normalized. RESULTS: Peak voxel-based level of significance for correlation between total fatigue score and PET uptake was localized to the right substantia nigra (T-score 4.67, p = 0.001). Similarly, SUVRs derived from atlas-based segmentation of the substantia nigra showed significant correlation with MFIS (r = 0.76, p = 0.004). On multiple regression, the right substantia nigra was an independent predictor of total MFIS (p = 0.02) and cognitive MFIS subscale values (p = 0.007), after adjustment for age, disability, and depression. Several additional areas of significant correlations with fatigue scores were identified, including the right parahippocampal gyrus, right precuneus, and juxtacortical white matter (all p < 0.05). There was no correlation between fatigue scores and brain atrophy and lesion load in patients with MS. CONCLUSION: Substantia nigra microglial activation is linked to fatigue in MS. Microglial activation across key brain regions may represent a unifying mechanism for MSAF, and further evaluation of neuroimmunologic basis of MSAF is warranted.


Assuntos
Fadiga , Microglia , Esclerose Múltipla , Substância Negra , Acetanilidas , Adulto , Fadiga/diagnóstico por imagem , Fadiga/etiologia , Fadiga/imunologia , Fadiga/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Microglia/imunologia , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/imunologia , Esclerose Múltipla/fisiopatologia , Tomografia por Emissão de Pósitrons , Substância Negra/diagnóstico por imagem , Substância Negra/imunologia
20.
JACC Cardiovasc Imaging ; 13(6): 1325-1336, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32417333

RESUMO

OBJECTIVES: The purpose of this study was to determine phenotypes characterizing cardiac involvement in AL amyloidosis by using direct (fluorine-18-labeled florbetapir {[18F]florbetapir} positron emission tomography [PET]/computed tomography) and indirect (echocardiography and cardiac magnetic resonance [CMR]) imaging biomarkers of AL amyloidosis. BACKGROUND: Cardiac involvement in systemic light chain amyloidosis (AL) is the main determinant of prognosis and, therefore, guides management. The hypothesis of this study was that myocardial AL deposits and expansion of extracellular volume (ECV) could be identified before increases in N-terminal pro-B-type natriuretic peptide or wall thickness. METHODS: A total of 45 subjects were prospectively enrolled in 3 groups: 25 with active AL amyloidosis with cardiac involvement (active-CA), 10 with active AL amyloidosis without cardiac involvement by conventional criteria (active-non-CA), and 10 with AL amyloidosis with cardiac involvement in remission for at least 1 year (remission-CA). All subjects underwent echocardiography, CMR, and [18F]florbetapir PET/CT to evaluate cardiac amyloid burden. RESULTS: The active-CA group demonstrated the largest myocardial AL amyloid burden, quantified by [18F]florbetapir retention index (RI) 0.110 (interquartile range [IQR]: 0.078 to 0.139) min-1, and the lowest cardiac function by global longitudinal strain (GLS), median GLS -11% (IQR: -8% to -13%). The remission-CA group had expanded extracellular volume (ECV) and [18F]florbetapir RI of 0.097 (IQR: 0.070 to 0.124 min-1), and abnormal GLS despite hematologic remission for >1 year. The active-non-CA cohort had evidence of cardiac amyloid deposition by advanced imaging metrics in 50% of the subjects; cardiac involvement was identified by late gadolinium enhancement in 20%, elevated ECV in 20%, and elevated [18F]florbetapir RI in 50%. CONCLUSIONS: Evidence of cardiac amyloid infiltration was found based on direct and indirect imaging biomarkers in subjects without CA by conventional criteria. The findings from [18F]florbetapir PET imaging provided insight into the preclinical disease process and on the basis of interpretation of expanded ECV on CMR and have important implications for future research and clinical management of AL amyloidosis. (Molecular Imaging of Primary Amyloid Cardiomyopathy [MICA]; NCT02641145).


Assuntos
Compostos de Anilina/administração & dosagem , Cardiomiopatias/diagnóstico por imagem , Ecocardiografia Doppler , Etilenoglicóis/administração & dosagem , Radioisótopos de Flúor/administração & dosagem , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Cardiomiopatias/patologia , Diagnóstico Precoce , Feminino , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/patologia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...